<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Flow Switch - Myko Electronics Pvt Ltd</title>
	<atom:link href="https://mykoelectronics.com/product-category/flow-measuring-instruments/flow-switch/feed/" rel="self" type="application/rss+xml" />
	<link>https://mykoelectronics.com</link>
	<description></description>
	<lastBuildDate>Wed, 29 Apr 2026 01:27:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://mykoelectronics.com/wp-content/uploads/2023/12/cropped-12569-comp-image-32x32.png</url>
	<title>Flow Switch - Myko Electronics Pvt Ltd</title>
	<link>https://mykoelectronics.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Water Flow Switch</title>
		<link>https://mykoelectronics.com/product/water-flow-switch/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=water-flow-switch</link>
					<comments>https://mykoelectronics.com/product/water-flow-switch/#respond</comments>
		
		<dc:creator><![CDATA[adminuser]]></dc:creator>
		<pubDate>Sat, 02 Mar 2024 11:00:19 +0000</pubDate>
				<guid isPermaLink="false">https://mykoelectronics.com/?post_type=product&#038;p=2721</guid>

					<description><![CDATA[<p>The paddle type SPDT WFS series are designed to provide excellent performance where accuracy, reliability, and rugged construction are<br />
required used in liquid flow lines carrying water or any fluid n either harmful to brass and prosphoras bronze nor classified as a hazard us fluids.<br />
They can be wired to close one circuit and open a second circuit when liquid flow either exceeds or drops below the adjusted flow rate . The WFS series are recommended for liquid pressure and temperature as mentioned below and must not be used on lines carrying liquid s below 0°C. These series may be used on liquids with high salt or chlorine content but is not for use in hazardous atmospheres. They may be also used outdoors but must be protected from weather or splashing water.</p>
<p>All series WFS flow switches are designed for use only as operating controls. Where an operating control failure would result in personal injury and/or<br />
loss of property, it is the responsibility of user to add safety devices that protect against, or supervisory systems that warn of control failure.</p>
<p>The post <a href="https://mykoelectronics.com/product/water-flow-switch/">Water Flow Switch</a> first appeared on <a href="https://mykoelectronics.com">Myko Electronics Pvt Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><strong>SPECIFICATIONS</strong></p>
<ul>
<li>Operating Pressure 10kgf/cm² (1000KPa)</li>
<li>Withstand Pressure 17.5Kgf/cm² (91750KPa)</li>
<li>Insulation Resistance Over 100 ohm , DC500VM</li>
<li>Withstand Voltage AC1500V/1minute</li>
<li>Contact Point Life 1000K Cycle</li>
<li>Bellows Life 500K Cycle</li>
<li>Temperature of Fluid Max 100°C (212°F)</li>
</ul><p>The post <a href="https://mykoelectronics.com/product/water-flow-switch/">Water Flow Switch</a> first appeared on <a href="https://mykoelectronics.com">Myko Electronics Pvt Ltd</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://mykoelectronics.com/product/water-flow-switch/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Oil Flow Switch</title>
		<link>https://mykoelectronics.com/product/oil-flow-switch/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=oil-flow-switch</link>
					<comments>https://mykoelectronics.com/product/oil-flow-switch/#respond</comments>
		
		<dc:creator><![CDATA[adminuser]]></dc:creator>
		<pubDate>Fri, 22 Dec 2023 16:09:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.rareign.com/myko/?post_type=product&#038;p=2198</guid>

					<description><![CDATA[<p><strong>Certification-</strong> CE Certified<br />
<strong>Voltage-</strong> 200VDC<br />
<strong>Frequency-</strong> 50HZ<br />
<strong>Fluid-</strong> Liquid &#38; Gas<br />
<strong>Density-</strong> Upto 2.95<br />
<strong>Voscosity-</strong> Upto 20 cp<br />
<strong>Warranty-</strong> 1 Year</p>
<p>The post <a href="https://mykoelectronics.com/product/oil-flow-switch/">Oil Flow Switch</a> first appeared on <a href="https://mykoelectronics.com">Myko Electronics Pvt Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>A Flow switch is normally a simple device that monitors flow and sends a trip signal to another device such as a Pump to protect it. Flow switches are used for Pump protection, Cooling Circuit protection, high & low flow rate alarm and general flow monitoring.</p><p>The post <a href="https://mykoelectronics.com/product/oil-flow-switch/">Oil Flow Switch</a> first appeared on <a href="https://mykoelectronics.com">Myko Electronics Pvt Ltd</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://mykoelectronics.com/product/oil-flow-switch/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
